15mm Pyrostop EI30 - 30/30

SKU: TGSO-15MMPYROSTOPEI30

Fire Rated Glass — Request a Quote

Fire rated glass is manufactured to order to your exact specification. Complete the form below and we'll come back to you with a detailed quote.

mm
mm
Processing required (optional)

Select any that apply. Suitability and pricing will be confirmed in your quotation.

Or call / WhatsApp: 07787 704925

Processing Options
Sandblasting
Request a frosted finish as part of your quotation.
Ritec ClearShield Coating
Request an easy-clean coating as part of your quotation.
Cut-outs
Describe your required cut-outs in the enquiry notes.
Request these options in the enquiry form above. Suitability and pricing will be confirmed in your quotation. For bespoke requirements, call 020 7206 2492.
Applications & Uses
Steel framed fire doors (30/0 single glazed)
Timber framed fire doors (30/0 single glazed)
Aluminium framed fire doors — SAPA system (30/0 single glazed)
Fire partitions and compartmentation in steel and timber systems
Not sure if this glass type suits your application? Call our team on 020 7206 2492 for free advice.

About This Product

15mm Pyrostop EI30 is a fully insulating, laminated fire-resistant glass providing 30 minutes of both integrity and insulation (EI30 classification). An interior-grade product with burglar resistance (P1A), it combines fire protection, security performance, and impact resistance for use in steel and timber framed fire doors and partitions.

Technical Specifications

  • Fire Classification: EI30
  • Fire Rating: 30 minutes Integrity / 30 minutes Insulation
  • Reaction to Fire: A2-s1,d0
  • Burglar Resistance: P1A
  • Thickness: 15mm
  • Thickness Tolerance: ±1mm
  • Impact Classification: 2(B)2 (EN 12600)
  • Sound Reduction: 38 dB (-1;-2)
  • U Value: 5.1 W/m²K
  • Light Transmittance: 0.87
  • g Value: 0.75
  • Temperature Tolerance: 40K
  • Grade: Internal
  • Standard: BS EN 13501-2
  • Certifire Certificate: CF328

Certified Applications

  • Steel framed fire doors (30/0 single glazed)
  • Timber framed fire doors (30/0 single glazed)
  • Aluminium framed fire doors — SAPA system (30/0 single glazed)
  • Fire partitions and compartmentation in steel and timber systems

Frame Compatibility

  • Steel
  • Timber
  • Aluminium (SAPA systems)

Key Features

  • EI30 fire classification — 30 minutes integrity and insulation
  • Reaction to fire class A2-s1,d0 — virtually non-combustible
  • Burglar resistance P1A — combined fire and security product
  • 2(B)2 impact classification — meets safety glazing requirements
  • 38 dB sound reduction — good acoustic separation
  • Fully laminated insulating construction
  • Interior use only
  • Certifire approved (CF328)

Important Information

Fire-rated glass must only be used as part of an appropriately approved and tested glazing system. Installation should be carried out by FIRAS-approved specialists in accordance with the relevant Certifire certificate specifications.

  • Edge clearance: 4–5mm required
  • Lateral clearance: 4–5mm required
  • Rebate depth: minimum 20mm
  • Operating temperature range: -20°C to +40°C
  • Store in dry, ventilated conditions away from direct sunlight
  • Never allow water contact with glass edges