Pyrobel 25 EI60 - 60/60
Fire Rated Glass — Request a Quote
Fire rated glass is manufactured to order to your exact specification. Complete the form below and we'll come back to you with a detailed quote.
Technical Specifications
| Thickness | Multiple options available — see product title |
| Standard / Certification | BS EN 13501-2 (Fire Resistance Classification) |
| Maximum Area | Please contact us for maximum size guidance |
| Lead Time | Confirmed in your order confirmation email |
| Edge Treatment | Machine polished as standard |
| Finish | Clear / as specified — tinted options available on request |
Processing Options
Applications & Uses
About This Product
Pyrobel 25 EI60 is a multi-laminated fire-resistant glass providing full 60 minutes of both integrity and insulation (EI60 classification). An internal-grade product, it is designed for the highest level of fire compartmentation in commercial buildings, providing a true thermal barrier against fire spread through glazing.
Technical Specifications
- Fire Classification: EI60
- Fire Rating: 60 minutes Integrity / 60 minutes Insulation
- Thickness: 26.6mm (nominal 25mm)
- Thickness Tolerance: ±2mm
- Weight: 60 kg/m²
- Glazing Type: Single
- Grade: Internal
- Standard: BS EN 13501-2
- Certifire Certificate: CF377
Certified Applications
- Steel doorsets (60/60 single glazed)
- Timber doorsets — hardwood (60/60 single glazed)
- Timber doorsets — softwood (60/60 single glazed)
- Steel framed screens (60/60 single glazed)
- Timber framed screens — hardwood (60/60 single glazed)
- Timber framed screens — softwood (60/60 single glazed — clear and wired)
- IGUs in steel framed screens (60/60)
- IGUs in timber framed screens (60/60)
Frame Compatibility
- Steel
- Timber (hardwood and softwood)
Key Features
- EI60 fire classification — full 60 minutes integrity and insulation
- Multi-laminated construction with intumescent interlayers
- Intumescent layers expand at 120°C to maintain fire barrier
- Butt-jointed glazing applications possible in steel systems
- Interior and exterior use (depending on glass type)
- Certifire approved (CF377)
Important Information
Fire-rated glass must only be used as part of an appropriately approved and tested glazing system. Installation should be carried out by FIRAS-approved specialists in accordance with the relevant Certifire certificate specifications.
- Edge clearance: 4–5mm required
- Lateral clearance: 4–5mm required
- Rebate depth: minimum 20mm
- Operating temperature range: -20°C to +40°C
- Store in dry, ventilated conditions away from direct sunlight
- Never allow water contact with glass edges